Thermalico

Contractor-first HVAC telemetry platform

Know before the homeowner calls.

A 30-minute telemetry install on any residential split system, and a dashboard your dispatcher checks first thing every morning. Failing fans, low charge, short cycling — caught while they are still a scheduled visit, not a 2 pm emergency in July.

Patel Family — Upstairs AC

R-454B split system · claimed 14 months ago

Cooling · steady
Supply air
54.2 °F
Return air
73.8 °F
Delta-T
19.6 °F
Superheat
9.1 °F
Subcool
10.4 °F
Compressor
2.85 kW

Watkins Residence — condenser fan current trending low

Likely causes, cheapest first: fan capacitor · motor bearings. Caught before the system overheats — not after.

31 readings per system, every minute, on every system you install.

Up and running in one service call.

01

Install in 30 minutes

Two boards: one in the air handler closet, one at the outdoor unit. No refrigerant work, no panel rewiring. WiFi setup happens on-site through a captive portal.

02

Scan the claim card

Every kit ships with a QR card. One scan and the system attaches itself to your shop's fleet — customer, address, equipment, done.

03

Watch every system

Return, supply, suction, liquid, discharge, blower power, thermostat calls — 31 readings a minute flow into one fleet view, with alerts that tell you what to check first.

Six weeks of data. One avoided emergency.

One reading of thirty-one: supply-air delta-T sliding out of its commissioning baseline as a filter loads up. The anomaly engine flags the drift at the threshold — weeks before the coil ices up and the “no cooling” call comes in.

12°16°20°24°alert thresholdsix weeks agotodaydelta_t_low firedlikely cause: dirty filter — visit scheduledfilter swapped — back in band
Supply-air Δ-T, °FCommissioning baselineAlert thresholdIllustrative data

31

readings per system, every minute

10 + 11

fault rules + cross-sensor sanity checks

30 min

install, no refrigerant work

3

refrigerants: R-410A · R-454B · R-32

Built for the shop, not the gadget shelf.

Cut the 2 pm callback in July

Outdoor fan failure, low charge, short cycling, dirty filters — caught before the system overheats and shuts down. Dispatch a tech on your schedule, not the homeowner's.

Coach the diagnosis

Every alert ships with the most-likely causes in cheapest-to-check order and a recommended next action. Junior techs close more tickets on the first visit.

Sell the maintenance contract

Show the homeowner a year of their own performance data. The trend line does the upselling for you.

Own the customer relationship

When something breaks, the homeowner taps a button that opens a service request with you. They never shop your competitor.

A smart thermostat sees the room. Thermalico sees the machine.

ThermostatsThermalico
Sees inside the HVAC — refrigerant, electrical, airflow
One dashboard for every system your shop installed
Diagnostic alerts, not just temperature
R-410A · R-454B · R-32, tracked per system
Revenue share back to the installer
Your data, exportable — never held hostage

Pricing that pays you back.

A shop with 50 systems on Connect earns ~$1,500 a year in revenue share and pays $99 a month for the dashboard — net positive before counting a single avoided callback.

Hardware

One-time, near cost

  • Core — indoor air-handler board
  • Pro — indoor + outdoor condensing-unit board
  • WiFi + offline SD buffer on both

Pro Fleet

The contractor dashboard, no row caps

  • Up to 10 systemsFree
  • 11 – 50$99 / mo
  • 51 – 200$299 / mo
  • 200+$799 / mo

Connect

The homeowner side

  • $99 / device / year
  • 30% goes to you, the installing shop
  • Alerts, performance history, contact-your-shop button

Start with a free pilot kit.

We install one on your service truck or your own house. You watch the data for a week. No commitment — and we waive Pro Fleet for your first customer install.

hello@thermalico.com